PDF download Download Article PDF download Download Article

In an electronic circuit, a diode is a small device that allows an electric current to flow through in only one direction. It works by having low resistance in one direction and high resistance on the other. You'll have to occasionally test a diode—which is typically made from a semiconductor material (like silicon in Group IV of the periodic table or selenium in Group VI of the periodic table)—to make sure it’s working properly. You can check the health of a standard diode with either a digital or analog multimeter, which will measure in ohms (Ω) or volts.

Method 1
Method 1 of 3:

Checking with an Analog Multimeter

PDF download Download Article
  1. Testing a diode while it is still in a circuit will not only throw off results, it's also incredibly dangerous. Remove the diode completely from the circuit or turn off the energy source, which could be an electrical outlet or battery.[1]
    • Discharging the capacitors to get rid of any extra voltage they hold will decrease your risk of an explosion or electric shock.
  2. This will be about 1 KΩ.[2] Setting the multimeter on low resistance allows some current to flow through without overloading the diode with too much.
    • The selector switch is the dial in the center of the multimeter.
    Advertisement
  3. The anode is the positive end, while the cathode is the negative end. The diode is now forward biased, meaning there is a current flowing through it.[3]
    • Any easy way to tell which end is the cathode vs. the anode, look for the silver stripe. That designates the cathode.
    • The leads have mini alligator clips at the ends which you'll use to attach to the diode.
  4. If your diode is forward biased, then the meter will read between 1 Ω and 100 Ω if it’s in working order. If the diode is reverse biased, then the reading on the meter should be infinite resistance, which means the diode is open. A lower resistance for either type of diode means the diode is shorted and needs to be replaced.[4] In either of these cases, you should replace your diode.
    • If you see no reading at all, make sure the leads are securely clipped onto the diode.
    • Check if your leads are functioning properly by testing them on a brand new battery. Set the multimeter to voltage mode and attach the red clip to the positive end and the black clip to the negative end. If the reading doesn't match the voltage of the battery, you need new leads.[5]
  5. It is now reverse biased, meaning no current is flowing through. You’ll get best results if you turn the dial to high resistance (about 100 KΩ) before clipping the leads into their new positions.[6]
    • High resistance is necessary here because reverse bias is meant to stop all current (or "resist" it) from flowing through.
  6. This signals a properly functioning diode.[7] If it gives a low resistance reading, the diode is defective and you should replace it.[8]
    • Replacing a diode can be as easy as swapping out standard batteries. However, you may have to do some light soldering on the ends to attach it to the circuit.
  7. Advertisement
Method 2
Method 2 of 3:

Using the Diode Mode on a Digital Multimeter

PDF download Download Article
  1. This is simply done by removing the energy source (often a battery) or causing a break in the circuit. You may need to discharge the capacitors to remove any leftover voltage, too. This is a safety measure that will prevent electrocution.
    • You can quickly discharge the capacitors by touching the two ends of a capacitor (known as the terminals) together.[9]
  2. This mode allows only a 2mA current to flow through the leads.[10] This level of current is high enough to produce a reading, yet not so high that the diode will fail.
    • It may also be labeled as “diode check” on your multimeter and is usually indicated by a small diode symbol.
    • The diode symbol will look like a triangle pointing towards a line.
  3. The red lead is positive and the black lead is negative.[11] This puts the current in the forward direction.[12]
    • The anode is positive and the cathode is negative. The cathode is often marked with a silver strip.[13]
  4. This meter reading means you have a healthy diode.[14] Anything outside of these numbers indicates that your diode isn't working properly and likely needs to be replaced.
    • If you don't see a reading on the multimeter, try disconnecting and reconnecting the leads (make sure you have the right ends connected).
    • Your multimeter may also have a bad battery or need new leads or clips. If the multimeter doesn't turn on at all, replace the battery. If the leads are frayed or if the clips are coming off the lead, replace the leads or clips.
  5. This puts the current in the reverse direction where no current will be flowing. The reading should be OL, which means open circuit.[15]
    • If you do get a voltage reading in this position, the diode is not working properly. Replace it with a new one.
    • You can buy a new diode at any electronics store like Best Buy, Radio Shack, or even Amazon.
  6. Advertisement
Method 3
Method 3 of 3:

Evaluating with the Ohmmeter Mode on a Digital Multimeter

PDF download Download Article
  1. Make sure there is also no remaining voltage. If you don't turn off the power, you risk causing an explosion or harming yourself or the diode with an electric current. Never take a reading in resistance mode while the diode is still in a circuit. It can throw off results.[16]
    • To cut the power, unplug the circuit from its power source, whether that's a battery or electrical outlet.
    • Discharge any capacitors to remove extra voltage. This is important when working on any electrical project to avoid electrocuting yourself.
  2. It should be indicated by the ohm (“Ω”) symbol. Set it at low resistance, or about 1 KΩ.[17]
    • A low resistance setting lets the current pass through the diode more easily.
  3. Placing the positive probe on the positive anode and the negative probe on the negative cathode makes your diode forward-biased.[18]
    • On many diodes, the anode is the black piece whereas the cathode is the silver strip.[19]
  4. [20] This implies the current is being conducted correctly.
    • If there's no reading displayed, double check that the leads are securely fastened to the ends of the diode.
    • Check that you've connected the proper leads—some multimeters actually switch the lead colors (so red is negative and vice versa).
    • If you still don't see a reading, try replacing the leads or battery. They may be dead.
  5. By attaching ends with opposite charges, you are stopping the diode from conducting current (if it is functioning correctly, that is). Your diode is now in reverse direction. Set it in high resistance, or about 100 KΩ.[21]
    • High resistance will prevent current from flowing through the diode.
  6. This open circuit reading (which also means infinite resistance) tells you that you have a healthy diode.[22] If you have a reading of any resistance, this signals your diode isn't functioning correctly as there should be no current flowing at all in this direction. Replace your diode with a new one.
    • New diodes can be purchased at an electronics store or online. If you aren't sure what type you need, ask an electrician.
  7. Advertisement

Expert Q&A

Search
Add New Question
  • Question
    My amplifier subwoofer is not working. I changed the capacitor but it still blowing the fuse. What could my problem be?
    Ralph Childers
    Ralph Childers
    Electrical Professional
    Ralph Childers is a master electrician based in the Portland, Oregon area with over 30 years of conducting and teaching electrical work. Ralph received his B.S. in Electrical Engineering from the University of Louisiana at Lafayette and holds an Oregon Journeyman Electrical License as well as electrician licenses in Louisiana and Texas.
    Ralph Childers
    Electrical Professional
    Expert Answer
    Sounds like a component, such as a resistor, has shorted causing too much current to flow to fuse.
Ask a Question
200 characters left
Include your email address to get a message when this question is answered.
Submit
Advertisement

Tips

Submit a Tip
All tip submissions are carefully reviewed before being published
Name
Please provide your name and last initial
Thanks for submitting a tip for review!

About This Article

Ralph Childers
Co-authored by:
Electrical Professional
This article was co-authored by Ralph Childers. Ralph Childers is a master electrician based in the Portland, Oregon area with over 30 years of conducting and teaching electrical work. Ralph received his B.S. in Electrical Engineering from the University of Louisiana at Lafayette and holds an Oregon Journeyman Electrical License as well as electrician licenses in Louisiana and Texas. This article has been viewed 118,683 times.
54 votes - 94%
Co-authors: 7
Updated: August 3, 2019
Views: 118,683
Article SummaryX

To make sure your diode is working properly, try testing it with an analog multimeter. Start by shutting off the diode’s power source and turning the selector’s switch to low resistance to allow some current to flow through without overloading the diode. Next, put the red lead on the anode, or the positive end, and the black lead on the cathode, or the negative end. Check the reading on the meter, which should be between 1 and 100 if your diode is healthy. Then, swap the red lead onto the cathode and the black lead onto the anode so no current is flowing through your diode. Turn the dial to high resistance and look for a reading of an open loop, which means you have a properly functioning diode. To learn how to use the diode mode on a digital multimeter, keep reading!

Did this summary help you?

Thanks to all authors for creating a page that has been read 118,683 times.